UK product ID: XPSVNE1142P. For zero speed detection. 24v dc. The xpsvne most common applications include providing the unlock signal for electrically interlocked sliding or removable machine guards, controlling rotation direction signals for reversing motors and engaging locking brakes after a motor has come to a standstill. The cabling between the motor windings and the inputs of the xpsvne module is also monitored to prevent a cabling breakage or anomaly being seen as a stopped motor. The input filters for standard xpsvne modules are designed for a frequency of up to 60 hz.For motors operating at a frequency higher than 60 hz, which therefore produce a high frequency remanent voltage, special modules xpsvne----hs should be used. The xpsvn is not compatible with wound rotor motors and is not designed to detect locked rotor conditions. The xpsvne modules incorporate 2 solid-state outputs for plc signalling and 4 leds to provide information on the monitoring circuit status. These modules also have two potentiometers mounted on the front cover to allow independent adjustment of the switching threshold for each input circuit. Reliable & durable electrical preventa safety relays by Schneider, buy online with confidence at best discount price and fast shipping to UK. Distributor product SKU: ZT1122692X.
Indicative Price: GBP 310
(for Actual Current Price, possibly lower, please click below)
UK product ID: XPSAFL5130P. For emergency stop, switch and safety light curtain monitoring. 24v ac/dc. Safety modules xpsafl meet the requirements of performance level pl e/category 4 conforming to standard en/iso 13849-1.
UK product ID: XPSATE5110. For emergency stop and switch monitoring. 24v dc. Safety modules xpsate are used for monitoring emergency stop circuits conforming to standards en/iso 13850 and en/iec 60204-1 and also meet the safety requirements for the electrical monitoring of switches in protection devices conforming to standard en/iso 14119.
UK product ID: XPSAR371144. For emergency stop, switch or safety light curtain monitoring. Safety modules xpsar meet the requirements of performance level pl e/category 4 conforming to standard en/iso 13849-1.
UK product ID: XPSDMB1132. For coded magnetic switch monitoring. 24v dc. Safety modules xpsdmb meet the requirements of performance level pl e/category 4 conforming to standard en/iso 13849-1. These safety modules are specifically designed for monitoring two independent sensors.
UK product ID: XPSAXE5120P. For emergency stop and switch monitoring. 24v ac/dc. Safety modules xpsaxe are used for monitoring emergency stop circuits conforming to standards en/iso 13850 and en/iec 60204-1. They meet the safety requirements for the electrical monitoring of switches in protection devices conforming to standard en/iso 14119.
UK product ID: XPSAK351144. For emergency stop, switch, sensing mat/edges or safety light curtain monitoring. Safety modules xpsak meet the requirements of performance level pl e/category 4 conforming to standard en/iso 13849-1.
UK product ID: XPSBCE3110P. For electrical monitoring of two-hand control stations. 24v ac/dc. Safety modules xpsbce meet the requirements of performance level pl e/category 4 conforming to standard en/iso 13849-1 and the european standard en 574/iso 13851 for two-hand control systems.
UK product ID: XPSAK311144. For emergency stop, switch, sensing mat/edges or safety light curtain monitoring. Safety modules xpsak meet the requirements of performance level pl e/category 4 conforming to standard en/iso 13849-1.
UK product ID: XPSBF1132. For electrical monitoring of two-hand control stations. 24v dc. Safety modules xpsbf meet the requirements of performance level pl e/category 4 conforming to standard en/iso 13849-1 and the european standard en 574/iso 13851 for two-hand control systems.
UK product ID: XPSAC3421. For emergency stop and switch monitoring. Safety modules xpsac are used for monitoring emergency stop circuits conforming to standards en/iso 13850 and en/iec 60204-1 and also meet the requirements for the electrical monitoring of switches in protection devices conforming to standard en 1088/iso 14119.
UK product ID: XPSDME1132. For coded magnetic switch monitoring. 24v dc. Safety modules xpsdme meet the requirements of performance level pl e/category 4 conforming to standard en/iso 13849-1. These safety modules are specifically designed for monitoring six independent sensors.
UK product ID: XPSAV11113. For emergency stop and switch monitoring. 24v dc. Safety modules xpsav are used for monitoring emergency stop circuits conforming to standards en/iso 13850 and en/iec 60204-1 and also meet the safety requirements for the electrical monitoring of switches in protection devices conforming to standard en/iso 14119.
UK product ID: XPSATE5110P. For emergency stop and switch monitoring. 24v dc. Safety modules xpsate are used for monitoring emergency stop circuits conforming to standards en/iso 13850 and en/iec 60204-1 and also meet the safety requirements for the electrical monitoring of switches in protection devices conforming to standard en/iso 14119.
UK product ID: XPSAR311144. For emergency stop, switch or safety light curtain monitoring. Safety modules xpsar meet the requirements of performance level pl e/category 4 conforming to standard en/iso 13849-1.
UK product ID: XPSAFL5130. For emergency stop, switch and safety light curtain monitoring. 24v ac/dc. Safety modules xpsafl meet the requirements of performance level pl e/category 4 conforming to standard en/iso 13849-1.